Email : Sales@safelectron.com
FPLR Riser Non Shielded Fire Alarm Cable, 300/500VConductors:6 cores x 14AWG fully annealed solid bare copper6 cores x 16AWG fully annealed solid bare copper .6 cores x 18AWG fully annealed solid bare copper6 cores x 20AWG fully annealed solid bare copperInsulation:Premium PVC (Polyvinyl Chloride), Heat Proof/ FPLR/ LSZHJacket:Premium PVC - Red, Riser RatedTemperature Range -20°C to +70°CFPLR Jacket, Pass both UL test 1421 and the Vertical Riser test UL 1666Applications:Fire AlarmsSignal MonitorsSignal Detection SystemsAudio Control CircuitsRequest:1Rated Voltage: 300/500 V2Temperature Rating: -20°C to +70°C3Standard: Pass both UL test 1421 and the Vertical Riser test UL 1666
Shielded Fire Alarm Cable, FPLR/ LSZH, Heat-Proof, ULFPLR Riser Non Shielded Fire Alarm Cable, 300/500VConductors:6 cores x 14AWG fully annealed solid bare copper6 cores x 16AWG fully annealed solid bare copper .6 cores x 18AWG fully annealed solid bare copper6 cores x 20AWG fully annealed solid bare copperInsulation:Premium PVC (Polyvinyl Chloride), Heat Proof/ FPLR/ LSZHDrain Wire1 x 20AWG Solid annealed bare copper1 x 22AWG Solid annealed bare copperShieldAluminum foilJacket:Premium PVC - Red, Riser RatedTemperature Range -20°C to +70°CFPLR Jacket, Pass both UL test 1421 and the Vertical Riser test UL 1666Applications:Fire AlarmsSignal MonitorsSignal Detection SystemsAudio Control CircuitsRequest:1Rated Voltage: 300/500 V2Temperature Rating: -20°C to +70°C3Standard: Pass both UL test 1421 and the Vertical Riser test UL 1666
*Oxygen-free Copper Wires*FPLP/ LSZH Shielded Fire Alarm Cable, Red, AWG size: 20/2, 18/2, 16/2, 14/2*For Fire alarm, smoke detectors, signaling, fire protective circuit installation wiring*Power limited fire alarm and communications cable for plenum applications*100m/ 200m/ 305m/ 500m PackUnshielded Fire Alarm CableSection AreaConstructionInsulation OD (mm)Overall Dia. (mm)2 Cores Fire Alarm Cable2C*0.5mm22C*1/0.8mm1.404.402C*0.75mm22C*1/0.98mm1.605.002C*1.0mm22C*1/1.13mm1.955.502C*1.5mm22C*1/1.38mm2.206.202C*2.5mm22C*1/1.78mm2.807.602C*4.0mm22C*7/0.85mm3.809.603 Cores Fire Alarm Cable3C*0.5mm23C*1/0.8mm1.404.603C*0.75mm23C*1/0.98mm1.605.203C*1.0mm23C*1/1.13mm1.955.803C*1.5mm23C*1/1.38mm2.206.403C*2.5mm23C*1/1.78mm2.808.003C*4.0mm23C*7/0.85mm3.8010.004 Cores Fire Alarm Cable4C*0.5mm24C*1/0.8mm1.405.204C*0.75mm24C*1/0.98mm1.605.804C*1.0mm24C*1/1.13mm1.956.404C*1.5mm24C*1/1.38mm2.207.604C*2.5mm24C*1/1.78mm2.809.004C*4.0mm24C*7/0.85mm3.8011.00
FPLP/ LSZH Unshielded Fire Alarm Cable, Red, AWG size: 20/4, 18/4, 16/4, 14/4For Fire alarm, smoke detectors, signaling, fire protective circuit installation wiringPower limited fire alarm and communications cable for plenum applications100m/ 200m/ 305m/ 500m PackFPLR Riser Non Shielded Fire Alarm Cable, 300/500VConductors:2 cores x 14AWG fully annealed solid bare copper2 cores x 16AWG fully annealed solid bare copper2 cores x 18AWG fully annealed solid bare copper2 cores x 20AWG fully annealed solid bare copper4 cores x 14AWG fully annealed solid bare copper4 cores x 16AWG fully annealed solid bare copper4 cores x 18AWG fully annealed solid bare copper4 cores x 20AWG fully annealed solid bare copperInsulation:Premium PVC (Polyvinyl Chloride), Heat Proof/ FPLR/ LSZHJacket:Premium PVC - Red, Riser RatedTemperature Range -20°C to +70°CFPLR Jacket, Pass both UL test 1421 and the Vertical Riser test UL 1666Applications:Fire AlarmsSignal MonitorsSignal Detection SystemsAudio Control CircuitsRequest:1, Rated Voltage: 300/500 V2, Temperature Rating: -20°C to +70°C3, Standard: Pass both UL test 1421 and the Vertical Riser test UL 1666
Oxygen-free Copper WiresFPLP/ LSZH Unshielded Fire Alarm Cable, Red, AWG size: 20/4, 18/4, 16/4, 14/4For Fire alarm, smoke detectors, signaling, fire protective circuit installation wiringPower limited fire alarm and communications cable for plenum applications100m/ 200m/ 305m/ 500m PackFPLR Riser Shielded Fire Alarm Cable, 300/500VConductors:2 cores x 14AWG fully annealed solid bare copper2 cores x 16AWG fully annealed solid bare copper2 cores x 18AWG fully annealed solid bare copper2 cores x 20AWG fully annealed solid bare copper4 cores x 14AWG fully annealed solid bare copper4 cores x 16AWG fully annealed solid bare copper4 cores x 18AWG fully annealed solid bare copper4 cores x 20AWG fully annealed solid bare copperInsulation:Premium PVC (Polyvinyl Chloride), Heat Proof/ FPLR/ LSZHJacket:Premium PVC - Red, Riser RatedTemperature Range -20°C to +70°CFPLR Jacket, Pass both UL test 1421 and the Vertical Riser test UL 1666Applications:Fire AlarmsSignal MonitorsSignal Detection SystemsAudio Control CircuitsRequest:1, Rated Voltage: 300/500 V2, Temperature Rating: -20°C to +70°C3, Standard: Pass both UL test 1421 and the Vertical Riser test UL 1666
300/450V Fire Resistant XLPE Insulated 2 Core/ 4 Core 6mm 4mm 2.5mm 2.0mm 1.5mm armoured power cable.1. 2&4&6 Core Control Cable/ Fire Alarm2. PVC Insulated 3. Galvanized Steel Wires Armored 4. XLPE, LSZH PVC, Fire Retardant PVC JacketParameter1. Voltage Uo/U 300/450V2. Long-time working temperature should be lower than 75°C, should not be lower than 0°C.3. Minimum bending radius: minimum bending diameter is two times of cable diameter while test binding Application4 core power cable has good features such as resistance to high temperature, oil, water, wearing, acid, alkali, corrosion. Widely used as transmitting electricity and power distributing cable in chemistry, petroleum, generating power and metallurgy industry.
*Oxygen-free Copper Wires 1.5mm*FPLP/ LSZH Unshielded Fire Alarm Cable, Red. *For Fire alarm, smoke detectors, signaling, fire protective circuit installation wiring*Power limited fire alarm and communications cable for plenum applications*100m/ 200m/ 305m/ 500m PackUnshielded Fire Alarm CableSection AreaConstructionInsulation OD (mm)Overall Dia. (mm)2 Cores Fire Alarm Cable2C*0.5mm22C*1/0.8mm1.404.402C*0.75mm22C*1/0.98mm1.605.002C*1.0mm22C*1/1.13mm1.955.502C*1.5mm22C*1/1.38mm2.206.202C*2.5mm22C*1/1.78mm2.807.602C*4.0mm22C*7/0.85mm3.809.603 Cores Fire Alarm Cable3C*0.5mm23C*1/0.8mm1.404.603C*0.75mm23C*1/0.98mm1.605.203C*1.0mm23C*1/1.13mm1.955.803C*1.5mm23C*1/1.38mm2.206.403C*2.5mm23C*1/1.78mm2.808.003C*4.0mm23C*7/0.85mm3.8010.004 Cores Fire Alarm Cable4C*0.5mm24C*1/0.8mm1.405.204C*0.75mm24C*1/0.98mm1.605.804C*1.0mm24C*1/1.13mm1.956.404C*1.5mm24C*1/1.38mm2.207.604C*2.5mm24C*1/1.78mm2.809.004C*4.0mm24C*7/0.85mm3.8011.00