Email : Sales@safelectron.com
SAFELECTRON was founded in 2009, we establish 2 factories in China,
one for Cables and other factory speicial for Patch Panels & Keystone jacks.
FTP CAT6A, cat7 24PORTS 1U/19inch 24 Port Shielded Patch panel load with 24 jacks. It can be equipped with 19inch racks and cabinets. It's ideal for 10/100/1000Base-T and 10G Base-T Ethernet applications. The detachable rear strain relief bar organize the cables orderly and neatly
The unshielded modular Patch Panel is 2U 48 port that can be mounted into 19" racks and cabinets.Front frame with paper label transparent holder for different port identification. Back with T568A/B wring scheme for easy and fast termination. Double back bar for more cable management
The unshielded patch panel is 8P8C modular 24 port in front and 110 punch down connector blocks on the back .The Ethernet patch panel is designed for use in 19” racks and ideal for 10/100/1000Base-T and 10GBase-T Ethernet applications.The paper label with clear numbers for cable identification. The rear bar enables quick and easy cable management.
This toolless keystone jack comes with concise and compact design. The toolless means not having punching tool for termination,fast and easy installation. It supports both T568A/B wiring . The color label on the cap is visible for guiding. The jack meets Cat6A standard , also compatible with lower classes like CAT6.5E
This toolless keystone jack comes with concise and compact design. The toolless means not having punching tool for termination,fast and easy installation. It supports both T568A/B wiring . The color label on the cap is visible for guiding. The jack meets Cat6A standard , also compatible with lower classes like CAT6. also Cat5e.
Cable Length : 5m/10m/15m/20m/30m/40m/50m . This pre-terminated CCTV cable is perfect for transmitting audio video and power. Simplify the installation of surveillance systems by using one cable to carry audio video and power. The cable can connect to 720P, 960P, 1080P, 700TVL,1000TVL,1200TVL, HD-CVI, HD-TVI, HD-AHD HD-SDI 960H Security Cameras without interference or quality decrease. ● Premade Coaxial+Power Siamese Cable ● The inner conductor of coaxial (Video) cable is pure copper ● 2.1mm * 5.5mm DC power plug ● Transmit video signals and supply DC power for security cameras ● Compatible with 960H, AHD 720P/960P/1080P, HDCVI/HD-TVI/HD-SDI
We focus on creating the absolute best customer service experience and provide the highest quality products. With more than 15 years experience, we are able to understand your requests and clearly convert them to make your best products.
Used for end user lines or trunk lines, and can be deployed and connected to the equipment. The distribution frame is the most important component in the management subsystem, and it is the hub that realizes the cross-connection of the two subsystems, vertical trunk line and horizontal wiring. Patch panels are usually installed on cabinets or walls. By installing accessories, the distribution frame can meet the needs of UTP, STP, coaxial cable, optical fiber, audio and video. The distribution frames commonly used in network engineering include twisted pair distribution frames and optical fiber distribution frames. According to the place of use and purpose, it is divided into two categories: main distribution frame and intermediate distribution frame.
View MoreIt will be our 2022 new released product The product is combined with RJ45 keystone and RJ45 plug for easy and fast connection The shielded provide better performance, without tool to punch or crimp the cables
View MoreThe main distribution frame, referred to as MDF, is used to connect subscriber lines, trunk lines, and dedicated lines to the corresponding interface points of the telephone exchange for testing, wiring, and protection of internal equipment.The structure of MDF is divided into two sides, in-line and in-line. In-line can be installed and guaranteed, and the test row or wiring is installed in horizontal. For in-line trunk lines or dedicated lines that do not need protection, test racks or wiring bars can also be installed. The main distribution frame of the same model can be spliced to meet the needs of expansion. The main distribution frame of the subscriber exchange adopts the box type because of its small capacity. In the early days, the total distribution frame was large, with a maximum capacity of 303 loops per line. The security guard adopts 20-wire or 21-wire carbon lightning arrester and uses a hot coil to limit the current. The test row is 20 lines and adopts a four-line shrapnel type, and the lead-in and lead-out lines can be separated by separating the shrapnel. The new type main distribution frame is matched with the program-controlled switchboard to greatly reduce the size and weight, and each in-line can accommodate 1,000 lines. Ensure to arrange 100 loops per block, and use metal discharge tubes to prevent high voltage and overcurrent. Each test row has 128 lines, and the contact reeds can be separated, so that the lines can be easily separated for testing. The wires connected to the terminals have their own independent wire troughs, which are easy to install and maintain. The guarantee arrangement adopts the card connection method to connect, and the insulation layer of the wire does not need to be stripped when the card is connected. The test row adopts winding method for wiring. Both of these two wiring methods are simple, reliable, fast, and non-polluting. According to different occasions, the new type of distribution frame has wall-mounted, floor-standing, single-sided and double-sided types.The main functions of the main distribution frame are: ①Security function. It protects the subscriber line against high voltage or high current; ②wiring. Any user can choose the number in the office, and the trunk lines between different offices can choose to occupy the trunk modules in the office, and can connect the inter-office and related subscriber lines according to the needs of the dedicated line.Intermediate distribution frame, referred to as IDF, is a distribution frame that connects the incoming and outgoing lines between the internal telephone exchanges. According to its installation location, it can be divided into two types: the main distribution frame and the intermediate distribution frame of the switching equipment and the inter-machine distribution frame.The structure of IDF is also divided into two sides, in-line and horizontal, in-line connection of the equipment's outgoing line, and horizontal connection of the equipment's incoming line. Both in-line and horizontal lines are equipped with wiring strips. One side of the improved terminal block is winding. The other side is the wire bonding. The function of IDF is mainly to deploy the access lines between all levels of switching equipment in order to give full play to the role of all levels of switching equipment.
View More1. Crystal headThe method of connecting the crystal head has been posted many times in previous articles. Generally, it is crimped according to the line sequence of T568B: orange white-orange-green and white-blue-blue and white-green-brown and white-brown, arrange the lines The order of the cores, after cutting flat, insert the cores side by side into the crystal head according to the upward direction of the crystal head chip, and then put it into the 8P port of the network cable pliers, and press it.Tools: Use ordinary network cable pliers for Category 5 and Category 6, and special network cable pliers for Category 7 cables. No need to use the network cable pliers without crystal plug.2. ModuleThere are two ways to connect to the module, T568A and T568B. Generally, the T568B wire sequence is used for crimping. After the grooves are matched, use a wire cutter to punch the wire.When connecting the module, it is necessary to ensure a unified standard, which is the same as the crystal head, and there are numbers from 1 to 8 in the logo, which must be sorted in numerical order and then crimped.Tools: wire punching knife, no punching type module does not need to use wire punching knife.3. Distribution frameThe distribution frame also has two wiring methods, T568A and T568B, and the wiring method is also very simple. Take the six types of network cables as an example:Use a wire stripper to remove the outer cover and cross frame of the network cable;Then insert the core of the network cable into the card slot of the corresponding wire sequence;Then buckle the cable management ring into the slot and fix it with a cable tie to prevent it from falling off;Finally, install the distribution frame on the cabinet with cabinet screws.PS: The connection method of the patch panel is similar to that of the module, but the label of the wire sequence will be different for patch panels of different brands, so please pay attention to it when connecting.
View More